Showing results: 196 - 210 of 391 items found.
-
Fivestar HV Testing Equipment Co., Ltd.
Impulse voltage test systems are used for impulse voltage testing of transformers, cables, gas-insulated switchgears (GIS), insulators, arresters, and other high-voltage devices. The test systems generate lightning impulse voltage (LI, 1.2/50μs), chopping lightning impulse voltages (LIC, front time 1.2μs, front, crest or tail chopped), and switching impulse voltage (SI, 250/2500μs) in accordance with IEC 60060-1; as well as IEC 60076-3 for transformers, and IEC 62067, 60840 and 60502-1 for cables), etc. And it can be used for steeping and oscillating impulse test by adding some extra equipment.
-
SFH264 Series -
Shanghai Launch Electric Co., Ltd.
This series of generators are mainly used to generate tripe frequency induced voltage for high voltage transformers. It also could be used for transformers in insulation induced voltage withstanding tests among windings, turns, sections and phases.The device is composed of triple frequency generator, console and reactor, with good waveforms output, reliability, and easy operation. Devices in different specification could be customer-made on request.
-
DY100 -
Neutronics Manufacturing Co.
DY-100 is a new generation, fully automatic, transformer turns ratio tester designed for measuring ratio, ratio error of single and three phase transformers. The entire test is done automatically and quickly. Operator enters the test parameters and DY-100 tak es over; powers up the voltage, balances the bridge, takes the readings, and displays the results on the LCD screen. Prints testresults through its built-in printer. A key feature of the DY-100 is automatic measure transformer connection group. LV and HV windings are automatically isolated once the measurement is over. True portability is achieved by the lightweight (only 10 kg), single unit design housing the DY-100. The DY-100 is encased in an aluminum alloy cabinet.
-
T 2000 -
Altanova Group
T 2000 is a portable current transformer test set which allows to perform many different measurements such as saturation, ratio and polarity tests and CT winding resistance test. Substation maintenance and commissioning test equipment, T 2000 is extremely appreciated by electrical engineers for its high accuracy and portability.
-
KVIO-80 -
KV Hipot Power Test Equipment Co.,Ltd
Automatic Insulation Oil Breakdown Tester Is Used to carry on power frequency dielectric break down test on the transformer oil, capacitor oil, electric device, insulation tool etc.
-
WB2671A/WB2671B -
Lisun Electronics Inc.
• Output voltage: 0-5kV (AC/DC); • Cutoff current range: AC 0~20mA (WB2671A)/0~100mA (WB2671B); DC 0-20mA; • Test time: 1-60s; • Transformer capacity: 750VA.
-
HBVT -
Hention Electrical Equipment Co., Ltd.
HBVT Transformer Oil Breakdown Voltage Tester , in accordance with IEC156, is designed to check insulating oil’s dielectric strength.The test set is compact and portable, therefore suitable for field work.
-
Shanghai Launch Electric Co., Ltd.
Power frequency resonance testing transformer is mainly used for AC voltage withstand testing of power cables, power generator sets, power capacitors, and the test samples with large capacitance.
-
DVDF -
AJIT Electronics Co.
This test setup is generally used to perform induced voltage test on the transformers. This set up consists of the USED motor and generator combination to develop the required voltage and frequency. Both generating unit and the drive motor are mounted on a common metallic frame.
-
Kharkovenergopribor Ltd.
Primary current injection tests are carried out during commissioning and certification of various types of switchgear and current transformers (CT), as well as during diagnostics of grounding circuits, testing circuit breakers and other devices. Primary current injection testers can also be used for determining the terminals polarity and transformation ratio of current transformers, thermal testing of electrical devices, testing automatic reclosers and sectional disconnectors.
-
Cambridge Instruments & Engineering Co.
suitable to perform AC High Voltage Power Frequency test on transformers, motors, cables etc. Leakage current can be measured at desired pressure and this set can be used as a source for cable fault burning.
-
SCAR 10 -
Altanova Group
This MOV- Metal Oxide Varistor test system is the perfect device to perform analysis and diagnostics on metal oxide arrestors. It is supplied with a special current clip-on transformer designed for the measurement of current leakage.
-
TTRM 101 -
Scope T&M Pvt, Ltd.
SCOPE introduces state of the art precision single phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. TTRM 101 measures only turns ratio where as TTRM 102 along with turns ratio, measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single phase transformer in charged switchyard condition. The range of AC voltage selection offers high accuracy in measurement.Both the instrument have in-built TFT display with touch screen and thermal printer. The user friendly, simple instrument makes the testing more easy. With the touch keypad it is possible to enter required DUT information.The ratio results are displayed with % error. Internal non-volatile memory gives the provision of storing test results.Further data can be downloaded to PC or copied to memory stick through USB port provided.
-
Neutronics Manufacturing Co.
During installation,testing,especially if the protective gear is connected to the power line via a current transformer it is advisable to use our Primary Injection Test Set. Keeping this in mind a wide range of Primary Current Injection Test Sets are being manufactured by "NMC”.
-
Bushing Tap Adapter Kit -
Altanova Group
Bushing Tap Adapter Kit is designed to perform Capacitance and Tan Delta tests on power transformer bushings The kit can b e used with the following ISA Test Set STS 5000 TD 5000 STS 4000 TD 5000 TDX 5000.